
| Home Analysis Report | |
| Client(s): | John Doe |
| Property address: | 123 45th Ave Anytown, MN |
| Inspection date: | Monday, June 06, 2005 |
Thank
you for choosing me to be your Home Inspector. I am uniquely capable to acquaint
you with the intricacies of your new home, as I have over two decades of experience
in residential property maintenance and repair.
Additionally, I am nationally
certified to perform inspections by NACHI (the National Association of Certified
Home Inspectors).
As a member of the National Association of Certified
Home Inspectors, it is my fullest intention to provide you with an honest and
concise report. Your presence during the inspection process will provide you with
an introduction to the functionality and safety of your new investment, as I point
out both the areas of concern and the positive aspects of your new home.
I
thank you for the opportunity to serve you!
Robert J Anderson
"A
Home Inspection is a Non-Invasive Visual Examination of a Residential Dwelling.
Components may include any combination of mechanical, structural, electrical,
plumbing, or other essential systems or portions of the home, as identified and
agreed to by the Client and Inspector, such as: Roof ~ Exterior ~ Basement / Foundation
~ Heating Cooling ~ Plumbing ~ Electrical ~ Fireplace ~ Attic & Insulation
~ Doors, Windows & Interior."
From NACHI Standards of Practice
"There
are conditions that require the removal of some part of the building to observe,
measure, or test otherwise concealed construction. Such intrusive inspections
require some demolition and should be performed only with the permission of the
owner and by experienced, qualified mechanics."
-From the U.S. Department of
Housing and Urban Development's
Residential Rehabilitation Inspection Guide,
2000
- HOMES BEING INSPECTED DO NOT "PASS" OR "FAIL" -
A home inspector
merely discloses his or her findings and reports those findings to the client.
Everyone involved graduates to a state of higher learning, and the client can
now make better informed decisions about the purchase of a home and its future
needs of upkeep and repair.
Four key areas of most home/building inspections
cover the exterior, the basement or crawlspace areas, the attic or crawlspace
areas and the living areas. Inspectors typically will spend sufficient time in
all of these areas to visually look for a host of red flags, tell-tale clues and
signs or defects and deficiencies.
The inspected areas of a home/building
will consist of all of the major visible and accessible electro-mechanical systems
as well as the major visible and accessible structural systems and components
of a building as they appeared and functioned at the time and date of the inspection.
Inspectors typically do not provide warranties or guaranties with their
inspections and reports. Buyers should therefore not rely on the inspection as
any form of insurance policy against any latent, hidden, concealed or future defects
and deficiencies.
The following are also some key items that buyers should
remember and consider when reviewing their inspection reports:
* Inspections
are not code compliance evaluations.
* Inspection reports are not structural
engineering reports.
* Systems and components that are off during the inspection
are not tested or reactivated.
* Buyers should consult with and ask questions
of owners and their representatives.
* Roof inspections and their components
are typically done from street level with binoculars.
* Reports are confidential
and are meant exclusively for buyers, and not brokers or owners.
* Inspectors
typically will not find each and every defect in a building, hence buyers should
anticipate future typical defects and deficiencies.
* Further evaluation by
specialists is recommended for any areas showing defects/deficiencies.
* A
final walk-through inspection should be carried out the day before passing by
the new owners to double check the condition of the building.
![]() | Safety | Poses a risk of injury or death |
![]() | Major defect | Correction likely involves a significant expense |
![]() | Repair/Replace | Recommend repairing or replacing |
![]() | Repair/Maintain | Recommend repair and/or maintenance |
![]() | Minor defect | Correction likely involves only a minor expense |
![]() | Maintain | Recommend ongoing maintenance |
![]() | Evaluate | Recommend evaluation by a specialist |
![]() | Monitor | Recommend monitoring in the future |
![]() | Comment | For your information |
Table
of Contents
General information
Exterior
Detached
garage or carport
Roof
Electric
service
Water heater
Heating
and air conditioning
Attic
Plumbing and
laundry
Basement
Well
Kitchen
Living room/dining
room
Master bath
Master bath/upper
level
Bathroom 2/lower
level
Bedroom 1/first
level
Bedroom 2/upstairs
to left
Bedroom
3/upper right, Bedroom 4/end of hallway
Interior rooms
| General information | Return to table of contents |
![]() | 1) Numerous wall, floor and/or ceiling surfaces were obscured by large amounts of furniture and/or stored items, preventing a full evaluation of some areas. |
| Exterior | Return to table of contents |
![]() ![]() ![]() | 2)
One or more ground fault circuit interrupter (GFCI) receptacles didn't trip
with the inspector's test instrument. Recommend having a qualified, licensed electrician
evaluate and repair or replace receptacles or the wiring to the receptacles as
necessary. Exterior outlets were not GFCI protected. | |||
![]() ![]() ![]() ![]() | 3)
The perimeter grading slopes towards the structure in one or more areas. This
can result in water accumulating around the structure's foundation, or in basements
and crawl spaces if they exist. Accumulated water is a conducive condition to
wood destroying insects and organisms. Wet soil may also cause the foundation
to settle and possibly fail over time. Recommend grading soil so it slopes down
and away from the structure with a slope of at least 5% (10% or better is optimal)
for at least 6 feet. Since grading would not be possible in this area and since this is of major concern because of potential water infiltration and even flooding of the basement, recommend having this area evaluated by a licensed contractor specializing in this type of concern. There is already evidence of water infiltration at the threshold of the basement door. The threshold and lower part of the door jamb has decayed because of said infiltration and is in need of replacement. This issue needs immediate attention to prevent any further damage to the structure.
| |||
![]() ![]() ![]() | 4)
Recommend cleaning deck and treating with a waterproof sealant claiming to
waterproof, block ultraviolet light, and stop mildew. Consumer Reports
recommends these products: The deck and wood walk way appear to have never been treated with any type of above sealant. Recommend sealing and maintaining deck now and in the future as needed. Also some of the decking on the east deck is in need of repair. This should be done before sealing deck so new decking will also be sealed. | |||
![]() ![]() ![]() | 5)
Insulation exposed in this area. This area needs to be sealed in some way
as to prevent access by any rodents or insects to the attic area.
| |||
![]() ![]() | 6)
The exterior siding in some areas is failing. Recommend having a qualified
contractor evaluate and repair these areas.
| |||
![]() ![]() | 7)
One or more downspouts have no extensions, or have extensions that are ineffective.
This can result in water accumulating around the structure's foundation, or in
basements and crawl spaces if they exist. Accumulated water is a conducive condition
to wood destroying insects and organisms, and may also cause the foundation to
settle and possibly fail over time. Recommend making repairs as necessary such
as repairing or installing splash blocks or tie-ins to underground drain lines
so rain water is carried at least several feet away from the structure to soil
that slopes down and away from the structure. The extension in this area needs to be extended to carry any water away from the walk in basement area. This area is already a concern and water from this downspout will only add to the already existing problem.
| |||
![]() ![]() | 8)
One or more gutters are missing. This can result in water accumulating around
the structure's foundation, or in basements and crawl spaces if they exist. Accumulated
water is a conducive condition to wood destroying insects and organisms, and may
also cause the foundation to settle and possibly fail over time. Recommend having
a qualified contractor install gutters and downspouts where missing. Also recommend
installing extensions such as splashblocks or tie-ins to underground drain lines
where necessary to carry rain water away from the house. The only area that gutters have been installed was over the east entrance. Suggest adding gutters to the remaining structure. | |||
![]() ![]() | 9)
The facia trim has begun to pull away from structure in some areas. Recommend
evaluating and repairing any loose facia found around entire structure.
| |||
![]() | 10)
Soil is in contact with or less than 6" from siding and/or trim/windows. This
is a conducive condition for wood destroying insects and organisms,also possible
area for water infiltration and decaying wood and trim because of said clearance.
There are three egress windows with this condition. Suggest removing vegetation from these areas and removing rocks and soil to a level to which any wood or siding has at least a 6" clearance from any vegetation or soil. Preferably window wells should be installed to prevent soil from eroding back into window areas. Also none of these windows have trim installed. Would suggest installing trim to help maintain a good seal and to give windows a more finished appearance.
| |||
![]() | 11)
Wood trim around first floor window on south side of structure has decayed
and is in need of replacement.
| |||
![]() ![]() ![]() | 12)
Vegetation (trees, shrubs and/or vines) are in contact with the structure's
exterior. This is a conducive condition for wood destroying insects and organisms.
Vegetation can serve as a conduit for insects and may retain moisture against
the exterior after it rains. Recommend pruning or removing vegetation as necessary
so there's at least a one foot gap between all vegetation and the structure's
exterior. There are many plants close to the structure (including garage) which at the present time don't seem to be causing any problems but should be monitored and maintained to ensure they are not causing any problems.
| |||
![]() ![]() | 13)
The finish on the deck is worn and/or deteriorated. Recommend cleaning and
repainting deck. The finish in the west entrance deck is beginning to show evidence of wear. Should be monitored and maintained as needed. | |||
![]() ![]() | 14)
One or more wooden deck support posts are in contact with soil. This is a
conducive condition for wood destroying insects and organisms. However no damage
from wood destroying insects or organisms was found. It's recommended that there
be at least 6" of space between any wood and the soil below, even if the wood
is treated. If possible, recommend grading soil so a 6" distance to the soil below
is maintained. Otherwise recommend installing borate based Impel rods to prevent rot.
| |||
![]() | 15)
The substructure of the deck is excluded from the inspection due to limited
access because of the low height. (East entrance deck.) |
| Detached garage or carport | Return to table of contents |
![]() ![]() | 16)
Vegetation (trees, shrubs and/or vines) are in contact with the structure's
exterior. This is a conducive condition for wood destroying insects and organisms.
Vegitation can serve as a conduit for insects and may retain moisture against
the exterior after it rains. Recommend pruning or removing vegitation as necessary
so there's at least a one foot gap between all vegitation and the structure's
exterior. There doesn't appear to be any damage caused from vegitation but should be monitored and maintained to ensure any future damage.
| |
![]() | 17) Overhead door is in need of adjusting or greese as the door is binding when lifted. | |
![]() | 18) The interior perimeter of the garage is excluded from this inspection due to lack of access from stored items. |
| Roof | Return to table of contents |
![]() ![]() ![]() ![]() | 19)
When the composition shingles were installed a drip molding was not installed
first. This drip edge is installed to overhang the facia by 1/2 inch to prevent
water from running down face of facia. Also this drip allows shingles to overhang
facia and also prevent water from siphoning up and under shingles. Also many areas
along the roof edge the shingles were cut short of facia allowing water infiltration
to roof sheathing and possibly to other surrounding wood framing, this was evident
along the roof edge above west entrance where sheathing under shingles has decayed.
Many areas along roof perimeter also show evidence of the same condition. This
is a major concern as water infiltrating in these areas has already caused damage
and will only worsen with time. Recommend evaluation by a licensed roofing contractor
who can recommend what repairs will need to be done to repair this problem.
| |||||||
![]() | 20) Trees are overhanging roof and are within 10 feet of roof vertically. This is a conducive condition for wood destroying insects and organisms since organic debris is more likely to accumulate on the roof surface. Accumulated debris may cause water to enter gaps in the roof surface and leak into attic and/or interior spaces. Recommend pruning trees so they're at least 10 feet above roof, or don't overhang the roof. | |||||||
![]() | 21)
Nail head prtruding under shingles
| |||||||
![]() | 22)
Moss is growing on the roof. This is a conducive condition for wood destroying
insects and organisms which can lead to the premature failure of the roof and
subsequent leaks. Recommend treating moss during its growing season (wet months)
with a moss killer. For information on various moss treatment products and their
pros and cons, visit http://bryophytes.science.oregonstate.edu/page24.htm
|
| Electric service | Return to table of contents |
![]() ![]() | 23)
No smoke detectors are visible. Recommend installing smoke detectors as necessary
so a functioning one exists in each hallway leading to bedrooms, and in each bedroom.
For more information on smoke detectors visit http://www.cpsc.gov/cpscpub/pubs/5077.html Was told by owner that the smoke detectors were sitting on top of upper kitchen cabinets. This is not a good practice. | |
![]() ![]() | 24)
Exposed wiring exists in the main service panel due to covers missing from
open circuit breaker slots. Recommend installing covers in open slots. (RED ARROW)
| |
![]() ![]() | 25)
Legend for overcurrent protection devices (breakers or fuses) in the main
service panel is missing, unreadable or incomplete. Recommend installing, updating
or correcting the legend as necessary so it's accurate. (GREEN ARROW)
|
| Water heater | Return to table of contents |
![]() ![]() | 26)
The estimated useful life for water heaters is 8 to 12 years. This water heater
appears to be approaching this age. Recommend budgeting for a replacement in the
near future.
| |
27) Evidence
of leak from either water softener or water heater. Unable to determine which
one. The owner was aware of the leak and was going to have the two areas looked
at to determine which was leaking and was going to repair or replace which ever
one was defective.
|
| Heating and air conditioning | Return to table of contents |
![]() ![]() | 28)
The condensing line from the furnace should be looked at by the HVAC technician
when furnace is serviced. This line is extremely long and is being pumped straight
up. This may cause problems in the future if pump in system should fail.
| ||
![]() | 29)
Recommend that this system be inspected, cleaned, serviced and repaired if
necessary by a qualified heating and cooling technician now and annually in the
future. Electronic air filter appears to not be working. Have technicion evaluate and repair as needed. (green arrow)
| ||
30) The
condencing lines from air conditioner are in need of better and more support straps.
|
| Attic | Return to table of contents |
![]() ![]() | 31)
Everything appeared to be in serviceable condition. Ventilation was good.
There was some evidence of past bee infestation. Being that some members of the
family are allergic to bees caution should be taken whenever attic is entered
as to not threaten these family members to possible exposure.
|
| Plumbing and laundry | Return to table of contents |
![]() ![]() ![]() | 32)
Water pressure is below 40 psi, but the flow appeared to be adequate. 40-80
psi is considered to be the normal range for water pressure in a home. The inspector
performed a "functional flow test" during the inspection, where multiple fixtures
are run simultaneously, and found there to be adequate flow. For example, the
shower flow didn't decrease significantly when the toilet was flushed. If the client finds the flow to be inadequate, recommend having a qualified plumber evaluate and repair as necessary. Installing a pressure boosting system is one possible solution. For information on these systems, visit: http://www.low-water-pressure.com/ | |
![]() ![]() | 33) Recommend having septic tank inspected. Recommend pumping tank if last pumped more than 3 years ago. | |
![]() | 34) Laundry sink isn't anchored to wall or floor. Recommend having a qualified contractor securely anchor sink to wall and/or floor to prevent damage to water supply and/or drainage pipes and causing leaks. | |
35)
Main water shut off valve and water filter. Filter should be changed at regular
intervals depending on sediment in water. Use recommended filter cartridge for
this type filter.
|
| Basement | Return to table of contents |
![]() ![]() ![]() | 36) No ground fault circuit interrupter (GFCI) protection device is visible for the sump pump electric supply. Recommend having a qualified, licensed electrician determine if a GFCI protection device (receptacle or circuit breaker) exists for the sump pump and install one if missing to reduce the danger of electric shock. | |
![]() ![]() | 37)
Cover plate(s) are missing from one or more electric receptacle boxes. They
are intended to contain fire and prevent electric shock from exposed wires. This
is a safety hazard and poses a risk of both fire and shock. Recommend installing
cover plates over receptacle boxes where missing.
| |
![]() | 38)
The weatherstrip around one or more exterior entry doors is damaged and/or
deteriorated. Recommend replacing weatherstripping at entry door(s) where necessary.
| |
39) Support
beam is not supported properly on south end of basement. Recommend suppoerting
with larger wood post or steel post.
| ||
40) Support
beam is twisted and bowed. Suggest replacing with new straight beam.
| ||
41) The
floor joists have been cut and then repaired in this area (NW corner of basement)
causing the floor in the adjacent room to slope toward the center. Recommend installing
new joists in this area to prevent any further sagging and to fix the current
problem.
| ||
| 42) |
| Well | Return to table of contents |
![]() ![]() | 43) Recommend having the well water tested for bacteria by a qualified lab. |
![]() ![]() | 44)
This well pump has exceeded its estimated useful life of 20 years. The clients
should be aware that this pump may need replacing at any time. |
| Kitchen | Return to table of contents |
![]() | 45) No GFCI outlets present in sink area. Recommend having licensed eletricion istall as needed. | |
![]() | 46)
Insulation was found under kitchen sink. Unable to determine if there was
past freezing problems in this area. Suggest asking previous owner reason for
insulation and monitor to determine if this is a problem area.
| |
47)
Switch cover has open slot. Need to replace wth proper cover.
|
| Living room/dining room | Return to table of contents |
48)
Living room and dining room appear to be in adequate condition.
|
| Master bath | Return to table of contents |
49)
Whirlpool tub in master bathroom.
|
| Master bath/upper level | Return to table of contents |
![]() | 50)
Extension cords are being used as permanent wiring in one or more areas. They
should only be used for portable equipment on a temporary basis. Using extension
cords as permanent wiring poses a fire and shock hazard, and is an indication
that wiring is not adequate and should be updated. Recommend either removing extension
cords or having a qualified, licensed electrician evaluate and make modification
as necessary. For example, install additional circuits and/or electric outlets. The whirlpool tub was not hard wired. See recommendations above. |
| Bathroom 2/lower level | Return to table of contents |
| Bedroom 1/first level | Return to table of contents |
51)
Floor is sagging due to previously explained (basement are) problem.
|
| Bedroom 2/upstairs to left | Return to table of contents |
| Bedroom 3/upper right, Bedroom 4/end of hallway | Return to table of contents |
![]() | 52) Ceiling fan in this and other bedrooms in upstairs are very low due to low ceiling height. These fans could cause bodily harm to anybody who may come into contact with them. May consider removing fans to prevent any possible injury. |
| Interior rooms | Return to table of contents |
![]() ![]() ![]() | 53) 2-pronged receptacles rather than 3-pronged, grounded receptacles are installed in one or more interior rooms. This limits the ability to use appliances that require a ground (computers and some other electronic appliances) in these areas. If client intends to operate electronic devices requiring a ground, then recommend having a qualified electrian evaluate and install grounded receptacles where necessary and as per the current National Electric Code. |
![]() ![]() | 54)
This home was built before 1978, when laws were enacted in the US preventing
the use of lead paint in residential structures. Lead paint may be present, and
is a known safety hazard, especially to children but also to adults. It may cause
brain damage and retarded mental and physical development, among other things.
The paint found in and around this structure appeared to be intact and and most
likely encapsulated by more recent layers of paint that's not lead-based. However,
recommend following precautions as described in the following links to Consumer
Products Safety Commission website articles regarding possible lead paint. What You Should Know About Lead Based Paint in Your Home: Safety Alert - CPSC Document #5054 CPSC Warns About Hazards of "Do lt Yourself" Removal of Lead Based Paint: Safety Alert - CPSC Document #5055 |
![]() ![]() | 55) Walking on some sections of the floor results in squeaking or creaking noises. This is usually the result of substandard construction practices where the subfloor decking isn't adequately fastened (insufficient glue) to the framing below. In most cases, this is an annoyance only rather than a structural problem. Various solutions such as Squeeeeek No More and Counter Snap fasteners exist to correct this. Repairs to eliminate the squeaks or creaks may be more or less difficult depending on there being finished hardwood floors, carpeting over the subfloor, and/or clear access to the underside of the subfloor. Recommend having a qualified contractor evaluate and repair as necessary. |
![]() | 56) One or more doors don't latch when closed. Recommend making repairs as necessary such as adjusting latch plates or lockset mechanisms. |
![]() | 57) One or more bathrooms with a shower don't have an exhaust fan installed. Even if a window that opens exists, it may not provide adequate ventilation, especially during cold weather when the window is less likely to be opened. Recommend having a qualified contractor install an exhaust fan, duct and vent cap as per standard building practices in bathrooms with showers where missing. |
![]() | 58) No exhaust fan is installed in the laundry room. This can lead to excessive accumulation of moisture. Recommend having a qualified contractor install an exhaust fan with a timer, duct and vent cap as per standard building practices in the laundry room. |
![]() | 59)
No visible source of heat of AC. There was no visible source of heat or AC in neither the upstairs bedrooms or bathroom. The heat source for these rooms appears to be in the upstairs hallway. |
![]() | 60) Minor cracks found in ceiling. These are only a cosmetic concern. No action is recommended. |
![]() | 61) Minor cracks found in walls. These are only a cosmetic concern. No action is recommended. |
![]() Photo 24 Septic system alarm. |


![]() | This report was published with ReportHost, the premier web-based inspection report writing service. For more information visit http://www.reporthost.com/ |